REAL-MODEL CATALOG · V3.6

⚡ Match My Generator

Build your household load, explore generator headroom, and compare manufacturer-listed generator models.

1. Choose your appliances

Check appliances you expect to run at the same time. Edit running and starting watts using your equipment's actual documentation or nameplate. Values below are placeholders.

ApplianceRunning WStarting W

Starting W is the estimated total demand while that appliance starts, not an amount to add to its running watts. For loads without a startup surge, enter the same value in both fields.

2. Selected generator & fuel

Choose a real model and its fuel to populate the calculation panel automatically. Select “Custom / manual ratings” to enter your own verified ratings.

When a catalog model is selected, its continuous rating is locked to the published fuel-specific value. Peak wattage is only populated where recorded and verified in this catalog; an unknown peak does not invalidate the running-load calculation. Use the generator's continuous rating for the selected fuel and conditions. For a panel connection, enter the applicable verified limit of the generator outlet, cord, inlet and transfer equipment; the lowest applicable limit governs. Leave blank if not established.

A 50A × 240V connection has a nominal 12,000 VA limit, not automatically 12,000 W of usable power for every load. This prototype accepts a user-verified watt limit; it does not calculate current, power factor, per-leg loading, or electrical-code requirements.

3. Compare real generator models

Manufacturer-published fuel-specific continuous output; model specifications are linked individually. Running utilization is calculated from your selected appliances. Browse & compare lists dated published reference prices from manufacturers and retailers; check the linked seller for current prices.

Model / sourceSelect generatorType & fuelContinuous outputRunning utilizationPower connection / notes

Portable receptacles listed here are not a verified home-connection rating. The 30A / 50A labels identify outlet types only; usable power also depends on the model's outlet-specific limits, cord, inlet, transfer equipment, leg balance and loads. Installed standby generators do not use portable 50A cords. Standby motor-starting kVA is not interchangeable with a portable generator's advertised peak watts.

XP16000iHT ratings are fuel-specific manufacturer-published continuous output. Its two 50A outlets do not establish that one connection can deliver its full rated output; verify outlet, cord, inlet and transfer-equipment limits.

Free generator maintenance planners

Download a printable checklist and service log for your generator. Always follow your exact model’s owner’s manual for maintenance intervals and safe service procedures.

↓ Portable generator planner (PDF)↓ Standby generator planner (PDF)

Help improve Match My Generator

Found an incorrect specification, encountered a problem, or have an idea? Tell us what you think.

Send feedback ↗